Coinovo · Miners · Antminer S21e XP Hyd 3U
860 TH/s at 11,180 watts. 13.0 J/TH, which is rank 20 of 126 in this comparison.
Network hashrate 973 EH/s ·
Household prices per Eurostat, 2. Halbjahr 2025, including all taxes and levies. Your own tariff may differ considerably; cheap switching offers often sit ten cents below. Just type yours in.
The break-even electricity price is the price per kilowatt-hour at which earnings exactly cover the power bill. Below it the machine earns, above it the machine burns money. In central Europe that is the number almost everything turns on.
Not included: connection, cooling, power-supply losses, downtime and maintenance. Water cooling adds the loop itself, hosting adds the slot fee. Network difficulty rises over the long run, which lowers earnings at the same hashrate; the payback figure uses today's values and is therefore on the optimistic side.
The S21e XP Hyd 3U packs 860 TH/s into a rack unit and sits at 13 J/TH, solidly mid-field among the water-cooled machines. Per terahash it is cheap, because the density pushes the price down. As with every 3U unit: without a rack, three-phase power and a loop, the figure above is just a figure.
A model of the S21 generation that Bitmain introduced in 2024. The family ranges from the air-cooled base model to water and immersion variants for data centres. Among the 17 models of this family in the comparison, the Antminer S21e XP Hyd 3U ranks 5th on efficiency and 1st on hashrate.
Compared with the Antminer S21e XP Hyd (13.0 J/TH), the Antminer S21e XP Hyd 3U needs 0% more power per terahash and delivers 100% more hashrate.
Whether the machine pays off depends above all on your power price: power prices and profitability in 69 countries.
No. At 11,180 W the Antminer S21e XP Hyd 3U needs a high-current or 32 A connection like a wallbox and belongs in an installation done by an electrician.
The Antminer S21e XP Hyd 3U turns practically all of its 11,180 W into heat: about 268 kWh a day, as much as 5.6 fan heaters of 2 kW running non-stop.
As a 19-inch rack unit with water cooling it is built for data centres and needs a cooling loop and high-current power there.
| Model | TH/s | J/TH | Net/day | Break-even | Price |
|---|---|---|---|---|---|
| WhatsMiner M73S+ | 570 | 12.5 | – | – | — |
| WhatsMiner M76S+ | 416 | 12.5 | – | – | — |
| WhatsMiner M70S+ | 262 | 12.5 | – | – | — |
| Avalon A16XP | 300 | 12.8 | – | – | — |
| WhatsMiner M73S | 555 | 13.0 | – | – | — |
| Antminer S21e XP Hyd | 430 | 13.0 | – | – | — |
| Antminer S21e XP Hyd 3U | 860 | 13.0 | – | – | 8,261 € |