Coinovo · Miners · Antminer S23 Hyd 3U
1,160 TH/s at 11,020 watts. 9.5 J/TH, which is rank 3 of 126 in this comparison.
Network hashrate 973 EH/s ·
Household prices per Eurostat, 2. Halbjahr 2025, including all taxes and levies. Your own tariff may differ considerably; cheap switching offers often sit ten cents below. Just type yours in.
The break-even electricity price is the price per kilowatt-hour at which earnings exactly cover the power bill. Below it the machine earns, above it the machine burns money. In central Europe that is the number almost everything turns on.
Not included: connection, cooling, power-supply losses, downtime and maintenance. Water cooling adds the loop itself, hosting adds the slot fee. Network difficulty rises over the long run, which lowers earnings at the same hashrate; the payback figure uses today's values and is therefore on the optimistic side.
At 9.5 J/TH the S23 Hyd 3U is the most efficient machine in this catalogue and at the same time one of the cheapest per terahash. The catch is the form factor: 3U means a rack unit, so it needs a nineteen-inch rack, three-phase power and a water loop. For a hall it is the obvious choice; for a garage it is no candidate at all, however good the numbers look. 11 kW of connected load is not a domestic matter.
A model of the S23 generation, Bitmain's newest line. It pushes power per terahash clearly below the S21 models once more and is aimed mainly at large operators. Among the 6 models of this family in the comparison, the Antminer S23 Hyd 3U ranks 2nd on efficiency and 1st on hashrate.
Compared with the Antminer S23e Hyd 2U (10.0 J/TH), the Antminer S23 Hyd 3U needs 5% less power per terahash and delivers 34% more hashrate.
Whether the machine pays off depends above all on your power price: power prices and profitability in 69 countries.
No. At 11,020 W the Antminer S23 Hyd 3U needs a high-current or 32 A connection like a wallbox and belongs in an installation done by an electrician.
The Antminer S23 Hyd 3U turns practically all of its 11,020 W into heat: about 264 kWh a day, as much as 5.5 fan heaters of 2 kW running non-stop.
As a 19-inch rack unit with water cooling it is built for data centres and needs a cooling loop and high-current power there.
| Model | TH/s | J/TH | Net/day | Break-even | Price |
|---|---|---|---|---|---|
| Antminer S23 XP Hyd | 600 | 8.9 | – | – | — |
| SealMiner A4 Ultra Hyd | 886 | 9.4 | – | – | — |
| Antminer S23 Hyd 3U | 1,160 | 9.5 | – | – | 7,493 € |
| Antminer S23 Hydro | 563 | 10.0 | – | – | 10,800 € |
| Antminer S23e Hyd 2U | 865 | 10.0 | – | – | — |
| SealMiner A4 Pro Air | 336 | 10.9 | – | – | — |
| SealMiner A4 Pro Hydro | 680 | 10.9 | – | – | — |